Back PageNext Page
UV Pure® UV Systems with Crossfire Technology
Hallett NSF
Hallett NSF

• Minimum dose of 40 mJ/cm2 at end of lamp life
• Easy lamp change and visual quartz sleeve inspection – takes seconds
• No extra space required for lamp changes – easy installation
• Self cleaning – effective up to 50 grains hard (Upstream and Hallett)
• Air cooled – no overheating



UV Pure Cactus™ UV System
Hallett NSF Hallett NSF
Cactus UV System

Hallett NSF Hallett NSF

UV Pure® Cactus™ for Residential Applications

UV Pure Hallett™ UV System
Description Part #
8 GPM; 1"  120V R47
12 GPM  1"  120V R48

 

UV Pure Hallett™ UV System - NSF
Hallett NSF
Hallett™ UV System

Hallett NSF Hallett NSF


Hallet™ - NSF/ANSI 55 Class A Certified
Fail safe shut off solenoid valve, Power conditioner
and SS flex hoses included

UV Pure Hallett™ UV System - NSF
Description Part #
15XS; 15 GPM 1"; NSF H000001
30 GPM; 1"; NSF C000005
30 GPM; 1.5"; NSF C000006

 

UV Pure UPSTREAM™ UV System
Upstream
UPSTREAM UV System

Hallett NSF

Power conditioner and SS flex hoses included
Fail safe shut off solenoid valve optional

UP Pure UPSTREAM™ UV System
Description Part #
NC 10 GPM (75%UVT) R000001
NC 10 GPM (50%UVT) R000002
NC 15 GPM (75%UVT) 1" R000003
NC 15 GPM (50%UVT) R000004
NC 30 GPM (75%UVT); 1" R000005
NC 30 GPM (75%UVT); 1.5" W/O FLOW CONT R000006
Lamps
Description Part #
LAMPS (2); for CACTUS 8 R300207
LAMPS (2); for H13, NC 10-75, CACTUS 12 E300165
LAMPS (2); for H15xs, NC 10-50, NC 15-75 E300210
LAMPS (2); for H30, NC 15-50, NC 30 C300065
Quartz Sleeves
Description Part #
SLEEVE for CACTUS 8 Z400000
SLEEVE for H13 E300173
SLEEVE for NC 10-75, CACTUS 12 R400001
SLEEVE for H15xs, NC 10-50, NC 15-75 R400010
SLEEVE for H30 C300067
SLEEVE for NC 15-50, NC 30 R400012
Accessories
Description Part #
ASO 1" SOLENOID; H15XS,10-75 UPSTREAMS E500021
ASO 1.5" SOLENOID; NC 30-75 E500017
REMOTE WIRELESS MONITOR KIT R400054


 

 



Performance
• Features Crossfire™ Technology
• Laboratory tested to 40 mJ/cm2 dose, same as NSF 55 Class A standard.
• Competing brands are specified at only 30mJ/cm2 dose, which is potentially unsafe!
• Tested at end of lamp life, not at beginning as competing brands do.
• Tested at 50% and 75% UV transmittance of water (other brands test at virtually pure 95% UVT)
• Proprietary reflectors deactivate pathogens from 360°.
• Eliminates UV shadowing—a hazard found in all competing conventional systems.


Self Cleaning Mechanism
• Automatic mechanical quartz cleaning system ensures quartz NEVER fouls.
• Automatic purge valve ensures no fouling in low or no-flow conditions.
• No quartz breakage (quartz never has to be removed).
• Operates in extreme water hardness levels.


Monitor Alarm

• Patented dual sensor system monitors both UV output AND water quality.
• Monitors lamp output, water transmittance, water and air temperature.
• Indicates when water is not safe, diagnoses problems and keeps a record of all events.
• Notifies you when it’s time to change UV lamps (after a full year of continuous use).