Aquatec Booster & Delivery Pumps

6800 & 8800 Series Booster Pumps increase low feed pressure to RO systems which
improves quality and production. 5800 & 550 Delivery (Demand) Pumps transfer water
to an icemaker or wetbar.
Variable Speed
Pumps Solve the
problem of
variable pressure
fluctuations and
variable flow rates
on multiple
outlets. This pump
maintains constant
pressure & flow
rates. The ERP-1000 is used for energy recovery in RO applications. It
increases
efficiency by as much as 400% and saves up to 80% of normal waste water.
|
| 6100 Series LFO Booster Pump w/ Enclosure |
| Description |
Part # |
| CDP6100-LFO PUMP/CASE; W/FILTER |
CDP6100 |
|
6800 Series Booster Pumps increase low feed pressure to RO systems which
improves quality and production.

6800 Series Low Flow
Booster Pumps
|
6800 Low Flow Booster Pumps
(Order PSW and Transformer Separately) |
| Description |
Part # |
| CDP-LFO-1/4" JG; 2.0; NYLN; FLEX; 1 PK |
6840-2J03-B221S |
|
|
| Description |
Part # |
| CDP-LFO-1/4" JG; 2.0; NYLON; FLEX; 12 PK |
6840-2J03-B221 |
| 6800 Series Transformers |
|
| Description |
Part # |
| 100 VOLT 68 |
TAS104-19 |
| 120 VOLT 68 |
TAS114-19EP |
| 230 VOLT 68 |
TAS234-19EP |
|
8800 Series Booster Pumps increase low feed pressure to RO systems which
improves quality and production.

8800 Series High Flow
Booster Pumps
|
8800 High Flow Booster Pumps
(Order PSW and Transformer Separately) |
| Description |
Part # |
| CDP-HFO-3/8" JG; 2.5"; NYLON; UNIV-COMP. |
8851-2J03-B423S |
|
|
| 8800 Series Transformers |
|
| Description |
Part # |
| 100 VOLT 88 |
TACS104-48 |
| 120 VOLT 88 |
TACS114-48 |
| 230 VOLT 88 |
TACS234-48RF |
|

Tank Pressure Switch |
| Tank Pressure Switch - (PSW) |
| Description |
Part # |
| 40 PSI; 1/4" JG - ONLY USE WITH PERM PUMP |
PSW240-00 |
| 60 PSI; 1/4" JG - ONLY USE WITH PERM PUMP |
PSW260-00 |
| 80 PSI; 1/4" JG - ONLY USE WITH PERM PUMP |
PSW280-00 |
| 40 PSI; 3/8" JG - ONLY USE WITH PERM PUMP |
PSW340-00 |
| 60 PSI; 3/8" JG - ONLY USE WITH PERM PUMP |
PSW360-00 |
| 80 PSI; 3/8" JG - ONLY USE WITH PERM PUMP |
PSW380-00 |
|
5800 Delivery (Demand) Pumps transfer water
to an icemaker or wetbar.

5800 Series Delivery/
Demand Pumps
|
| 5800 Series Delivery / Demand Pumps |
| Description |
Part # |
| 0.7 GPM; 70/60 PSI; 3/8" JG: 120V CHORD |
5851-7E12-J574 |
| 0.9 GPM; 130/60 PSI;3/8"JG;120V W/O CHORD |
5852-1E13-B574 |
| 0.9 GPM; 130/60 PSI; 3/8" JG; 120V CHORD |
5853-1E12-J574 |
| 1.2 GPM; 70/60 PSI; 3/8" JG; 120V CHORD |
5852-7E12-J584 |
| 1.7 GPM; 130/60 PSI;3/8"JG;120V W/O CHORD |
5853-1E10-B524 |
| 1.7 GPM; 130/60 PSI; 3/8" JG; 120V CHORD |
5853-1E10-J524 |
| 1.7 GPM; 70/60 PSI; 3/8" JG; 120V CHORD |
5853-7E12-J524 |
Variable Speed
Pumps Solve the
problem of
variable pressure
fluctuations and
variable flow rates
on multiple
outlets. This pump
maintains constant
pressure & flow
rates.
| 5800 Series Variable Speed Delivery / Demand Pump |
| Description |
Part # |
| 0.1-1GPM; 40PSI; CHORD; 115V; 3/8" |
5853-GB12-V81D |
|
550 Delivery (Demand) Pumps transfer water
to an icemaker or wetbar.

550 Smart Pump
|
| 550 Series Super Flow Delivery / Demand Pumps |
| Description |
Part # |
| 3.2 GPM; 60 PSI; 1/2" F; 120V CHORD |
5512-1E12-J586 |
| 3.35 GPM;60 PSI;1/2" NPT;12VDC W/O CHORD |
5511-1E12-B638 |
| 5 GPM; 60 PSI; 1/2" F; 120V CHORD |
5513-1E12-J526 |
| 6 GPM; 60 PSI; 1/2" F; 120V W/O CHORD |
5513-1E01-B606 |
| 6 GPM; 60 PSI; 1/2" F; 120V; CHORD |
5513-1E01-J606 |
|
|
Variable Speed Pumps Solve the problem of variable pressure fluctuations and variable flow rates on multiple outlets. This pump maintains constant pressure & flow rates.
550 Series Variable Speed Delivery / Demand Pumps
(Requires Part # QTS-556) |
| Description |
Part # |
| SMART PUMP; 3.8 GPM; 60PSI; NO FITTING |
5501-1EN2-V77D |
| SMART PUMP; 4.5 GPM; 50PSI; NO FITTING |
5502-IDN2-V77D |
| SMART PUMP FITTING 1/2"M (2 PK) |
QTS-556 |
|
ERP 1000 Permeate
Pump:
• Non Electrical
• Improves water quality
• Increases recovery time
• Reduces waste water
The ERP-1000 is used for energy recovery in RO applications. It
increases
efficiency by as much as 400% and
saves up to 80% of normal waste water.

ERP 1000 Permeate
Pump
|
| ERP 1000 Permeate Pumps |
|
| Description |
Part # |
| 1/4" JG; (SINGLE PACK) |
ERP1000-JG-S |
| 1/4" JACO STRAIGHT |
ERP1000-01 |
| 1/4" JACO ELBOW |
ERP1000-02 |
|
|
| Description |
Part # |
| 1/4" JG (BULK - 30 PACK) |
ERP1000-JG |
|

Auto Flush Timers

Leak Detector

Tank Level Control
|
Auto Flush Timers
Order Wire Harness Separately) |
| Description |
Part # |
| 300 ML/MIN |
AFR603 |
| 400 ML/MIN |
AFR604 |
| 500 ML/MIN |
AFR605 |
| 600 ML/MIN |
AFR606 |
| 700 ML/MIN |
AFR607 |
| 800 ML/MIN |
AFR608 |
|
|
| Accessories |
|
| Description |
Part # |
| LOW PRESSURE PROTECTION SWITCH |
LPS340-G |
| LOW PRESSURE PROTECTION WIRE |
21-028 |
| LEAK DETECTOR; UNLATCHING |
LDS900 |
| 10' LEAK DETECTOR HARNESS SET |
21-160 |
| PUMP SEDIMENT FILTER W/O FITTINGS |
PSF-370 |
| TANK LEVEL CONTROL; 24VDC |
TLC-DC901 |
| TLC WIRE HARNESS SET |
21-075 |
| PUMPHEAD ASSY; 8811 |
8851-2J03 |
| UPPER HOUSING ASSY (6800) |
53-014-10 |
| LOWER HOUSING ASSY (6800) |
53-015-00 |
| DOUBLE WIRE HARNESS(11") F-MF |
21-127 |
LDS/TLC Features:
• Improves TDS rejection rate
• Extends membrane life
• Available with integrated flow restrictor
• Hermetically sealed circuitry
|

t